Sale

Oratect AOT-06 Saliva Drug Test Kit (25 Per Box)

$273.75 $206.25

  • Description
  • Test Procedure

Description

Oratect AOT-06 Saliva Drug Test Kit

The Oratect AOT-06 saliva drug test kit is an FDA 510(k) cleared drug test. Saliva drug testing for 6 drugs of abuse. Easy to use mouth swab drug test for employment – workplace drug testing.

 

Oratect saliva drug test for 6 drugs of abuse:

Cocaine (COC), Amphetamine (AMP), Opiates (OPI), Methamphetamine (mAMP), Phencyclidine (PCP)

 

Oratect Features and Benefits

  • Two test strip configurations of 6 drugs
  • No Bathroom required Test Anywhere
  • Rapid collection and testing in one step
  • Results in 5 minutes
  • User friendly and non-invasive
  • Avoids cross gender observation
  • Reduces sample adulteration or contamination
  • Transport tube included for confirmation testing
  • FDA (510K) Cleared
  • Mouth swab drug test
  • Free Online Training

 

Oratect Saliva Drug Test How It Works

 

Oratect AOT-06 Saliva Drug Test | U.S Screening Source                                Oratect AOT-06 Saliva Drug Test | U.S Screening Source

 

 

How to use the Oratect AOT-06 Saliva Drug Test – Mouth Swab Drug Test

Step 1. Remove the test device from the sealed pouch. Carefully remove the cap to expose the collection pad. Ensure that the blue lines are present in each test window. Hold the top portion of the device – above the test window area. Do not touch the test window area.

Step 2. Subject should keep head level. Open mouth and rub the collection pad inside mouth against one cheek in a circular motion approximately 15 – 20 times.  Then do the same on the opposite cheek. Rub the pad on top of the tongue several times then underneath the tongue. DO NOT CHEW, BITE OR SUCK THE COLLECTION PAD. Collection time is approximately 3 minutes.

Step 3. Remove device from the mouth when both windows begin to turn pink. (If no flow is observed after 5 minutes in the mouth, discard the device and repeat with a new device). Recap device, lay on flat surface. Do not read after 30 minutes. Negative results can be interpreted as soon as all test lines are visible. Wait 5 minutes to determine a positive result.

Please refer to complete instruction on the package insert and procedure card.

 

Reading the Results

Read the results when all upper “Control” or “C” lines have appeared. Negative results can be read as soon as all “Test” or “T” lines are visible. (Wait 5 minutes to determine a positive result).

Oratect Instructions

 

Oratect Saliva Drug Test Cutoff Levels & Detection Times

DrugCutoff LevelDetection Time
Amphetamine (AMP50 ng/ml1 - 3 Days
Cocaine (COC)20 ng/ml1 - 3 Days
Methamphetamine (MET)50 ng/ml1 - 3 Days
Opiates (OPI)40 ng/ml1 - 3 Days
Phencyclidine (PCP)10 ng/ml1 - 3 Days
Marijuana (THC)40 ng/ml6 - 12 Hours

 

Oratect Product Information

Saliva Drug Test Brochure

Procedure & Package Insert

Free Training Website

 

Sold in boxes of 25 tests

Two-part drug test results forms included.

Free Ground Shipping

For almost 20 years, we have been serving clients from all industries. We offer high quality products, competitive prices and superior customer service.

How to use the Oratect AOT-06 Saliva Drug Test – Mouth Swab Drug Test

Step 1. Remove the test device from the sealed pouch. Carefully remove the blue cap to expose the collection pad. Ensure that the blue lines are present in each test window. Hold the top portion of the device – above the test window area. Do not touch the test window area.

Step 2. Subject should keep head level. Open mouth and rub the collection pad inside mouth against one cheek in a circular motion approximately 15 – 20 times.  Then do the same on the opposite cheek. Rub the pad on top of the tongue several times then underneath the tongue. DO NOT CHEW, BITE OR SUCK THE COLLECTION PAD. Collection time is approximately 3 minutes.

Step 3. Remove device from the mouth when both windows begin to turn pink. (If no flow is observed after 5 minutes in the mouth, discard the device and repeat with a new device). Recap device, lay on flat surface. Do not read after 30 minutes. Negative results can be interpreted as soon as all test lines are visible. Wait 5 minutes to determine a positive result.

Please refer to complete instruction on the package insert and procedure card.

 

Reading the Results

Read the results when all upper “Control” or “C” lines have appeared. Negative results can be read as soon as all “Test” or “T” lines are visible. (Wait 5 minutes to determine a positive result). Oratect HM-15 Instructions